DataGauss LG MAX Degausser
The DataGauss is a powerful compact continuous hard drive degausser with an extra-large degaussing chamber capable of accommodating both standard and extra-large (full height) Hard Disk Drives and Backup Tapes. The DataGauss benefits from state-of-the-art pulse technology and a fast and powerful continuous operation, yet it is compact and simple to operate. Media that can be erased includes Hard Drives that use Perpendicular and Longitudinal recording techniques up to 5000 Oersted’s and all common backup tapes.
Simple Operation
Operators slide the catch and the lid lifts up automatically. Place the media into the media compartment and close the lid. The erase cycle is started by pressing the ‘erase’ button on the control panel which activates the charging of the powerful degaussing magnetic field. When the display says the degauss cycle is complete the lid can be opened and the media removed. The entire process takes just 45 seconds. Throughout the whole erase cycle the on board processor monitors the erase procedure ensuring that it is completed correctly. The operator is immediately alerted to any interruptions in the cycle by messages on the LCD control panel.
At all times through the cycle the safety interlocks ensure operators cannot put fingers, clothing etc in the crushing area whilst the moving parts are energized.
Safe, Secure and Compliant
With safety in mind and to meet the latest ICNIRP Magnetic Exposure Guidelines, the DataGauss field discharge duration is less than a second and the magnetic field is designed to be concentrated inside the chamber.
The DataGauss is designed to help you comply with the following Government Mandates that require destruction of sensitive information stored on Hard Drives and Tapes before they are disposal.
- PCI DSS (Payment Card Industry Data Security Standard)
- NIST (National Institute of Standard and Technology) Guidelines for Media Sanitization
- NIST SP 800-36
- NIST SP 800-88
- HIPAA (Health Information Portability and Accountability Act)
- PIPEDA (Personal Information Protection and Electronic Documents Act)
- GLBA (Gramm-Leach-Billey Act)
- California Senate SB-1386
- IRS-1075
- CJIS
DataGauss LG MAX - degaussing chamber with unique Erasure Log Software
The DataGauss LG MAX features unique Erasure Log System which provides a reporting tool and a record of media degaussed.
It can be used stand alone or, if connected to a PC or laptop via USB cable, can be used in conjunction with the Erasure Log Software. This will log all the information related to the erasure and provide a printed report if required. The information logged includes details of the: processing company (including the operator and supervisor); media owner; degausser machine type; serial number, part number and size of the Hard Drive or Tape. Information is entered onto the software via keyboard or optional barcode scanner to speed up the data entry if required.
When the logging program has been opened on the PC and the DataGauss LG MAX is connected, the operator simply clicks on the "Find Machine" button for all the unit details to be automatically entered into the log including model, serial number and firmware version. The DataGauss LG MAX display will show it is in remote mode controlled by the PC.
Further data regarding operator, customer and media is then entered via keyboard (or optional barcode scanner) before the Hard Drive or Tape is placed into the degausser and the lid closed. The erasure is commenced by clicking the "Destroy" button on the screen which activates the charging of the powerful degaussing magnetic field.
A window opens on the screen showing the progress of the degaussing cycle. When the display shows the degauss cycle is complete the lid can be opened and the media removed. The entire process takes just 45 seconds. Throughout the whole erase cycle the on-board processor monitors the erase procedure ensuring that it is completed correctly. The operator is immediately alerted to any interruptions in the cycle by messages on the screen.
The lower portion of the screen now shows all the details of the erasure including Date, Time, Media Serial number, Capacitor Voltage, Magnetic Gauss Field and confirmation that the media was degaussed successfully.
If this data is highlighted and the print button pressed all the details on the screen along with all the data entered will be printed as a report. As new media is erased the details will be added to the Media Processed Log in the lower half of the screen. By highlighting erase records, the logs of one or more can be printed as required.
There is a Supervisor Section in the Software which is Password protected. This allows the Supervisor to decide which fields are required and which fields must be completed by the Operator. The log record is stored in the PC and can be archived at any time or exported as a .csv file.
Erasure Log Manager Features
- Log software printable reports show:
- Processing Company
- Degausser Model & Serial No
- Media owner
Operator / Supervisor Name
- Media information
- Degaussing information
DataGauss Specifications
|
Features:
|
- Extra large degaussing chamber
- Pulse technology
- Fast continuous duty single pass operation
- Processor controlled for failsafe operation
- Complete erasure of hard drives and backup tapes
- Very low noise, suitable for office environment
|
Media Handling:
|
3.5", 2.5" & 1.8" hard drives 5000Oe. Longitudinal & perpendicular recording. DLT, S-DLT, LTO1, 2, 3, 4 & 5; 3480/3490/3490e, 3590, 9840 & T9940 & T1000 tape; Ultrium 7 redwood SD-3 tape & cartridges; Mammoth 1 & 2, 8mm, AIT1 & 2, M2 tape; DDS 1, 2, 3, 4 & 5, DD-2 & DFT-1 & 2
|
Media Handling:
|
3.5", 2.5" & 1.8" hard drives 5000Oe. Longitudinal & perpendicular recording. DLT, S-DLT, LTO1, 2, 3, 4 & 5; 3480/3490/3490e, 3590, 9840 & T9940 & T1000 tape; Ultrium 7 redwood SD-3 tape & cartridges; Mammoth 1 & 2, 8mm, AIT1 & 2, M2 tape; DDS 1, 2, 3, 4 & 5, DD-2 & DFT-1 & 2
|
Power Supply:
|
100-120 VAC, 208-240 VAC, 50/60Hz (Please specify Voltage and Frequency when ordering)
|
Current Rating:
|
50Hz 3.5 Amps, 60Hz 6 Amps Typical
|
Degaussing Force:
|
10,000 max gauss
|
Cycle Time:
|
45 seconds
|
Dimensions (WxHxD):
|
13.9" x 9.7" x 14.3" - (35 x 24.6 x 36cm)
|
Packed Dimensions:
|
18.5" x 13.4" x 18.5" - (47 x 34 x 47cm)
|
Unit Weight:
|
49lbs (22kg)
|
Packed Weight:
|
53lbs (24kg)
|
Controls:
|
On/Off Power Switch, Erase button
|
Indicators:
|
Liquid Crystal Display (LCD)
|
Throughput:
|
70 hard drives/cartridges per hour typical
|
Controls:
|
Bi Universal Serial Bus. 2.0 Full Speed (USB)
|
Warranty:
|
24 months back to base, all parts & labor included.
Extended warranties available
|